Optimization of Decanter Variables
The variables that can be adjusted in the field on startup, testing, or optimization of a standard design solid bowl decanter are: Bowl speed or G-force, Feed rate, Differential RPM The liquid level in the bowl (pond level) There are also very rare variables that occasionally benefit the separation, 5) Rare adjustments. And, 6), One [...]